The Thawzall TCH150 Hydronic-Glycol Ground Heater model is well suited for small to medium size jobs. Use as emergency backup for installed heating systems. Thawzall’s patented HEATZONE® technology THAW’s faster, CURE’s concrete more uniformly and provides dry, flameless HEAT to winter construction jobs

Thawzall and Wacker have both discontinued their smaller Ground Heaters, but please contact us for current availability (shorter lead times) in the HeatKing line-up.

Thawzall TCH150 Brochure (click for pdf)

IMPROVEMENTS MADE IN FUNCTION AND DESIGN

■ Newly designed “series flow pattern” provides more flow for better heat transfer – over 30 GPM – better heat transfer rate. ■ Easy Operator Interface – newly designed Control box located at rear passenger side.  All controls in one place – for easier operator interface.  OFF/ON switch allows for untrained operator use.  Set temperature delivery – allows for consistent uniform heat transfer for accurate cold weather concrete curing.  Return Temperature Displays – Monitors heat transfer for peace of mind.  Fuel gauge and low water alert are added to the control box for trouble shooting. ■ Flow is increased through larger sized and shorter piping, resulting in faster thawing and, used with available unit heaters, more efficient heat distribution. ■ New Power/In-Power/out and free-wheeling feature for reel operation with dynamic brake

PERFORMANCE SPECIFICATIONS:

  • THAW frozen ground sq ft 1,200 – 2,400 sq m 110-220
  • CURE concrete sq ft 2,400 sq m 220 with accessories sq ft 6,000 max sq m 550 max
  • FROST prevention sq ft 2,400 sq m 220 with accessories sq ft 10,800 max sq m 1,000 max
  • HEAT buildings cu ft 210,00 cu m 5,900
  • Input/Output MBH* 175/148
  • Operating Range °F 180 °C 82
  • Operating Pressure psi 1-5
  • Fuel Consumption (max) gph 1.0 lph 3.8 Run Time days 4+
  • Pump Capacity gpm/gph 30/1800 lpm/lph 110/6,800

DIMENSIONS & CAPACITIES:

  • L x W x H in 161 x 174 x 79 cm 409 x 190 x 200
  • Weight w/fuel & fluid lbs 3,460 kg 1,570
  • Optional Generator lbs 500 kg 230
  • Fuel Capacity gal 102 liters 390
  • HTF (Heat Transfer Fluid) gal 56 liters 212

MISC. SPECIFICATIONS:

  • One – 1/2 hp Pump Closed Loop
  • Centrifugal Hose Length (2 zones x 600’) ft 1,200 (2 zones x 182m) m 365
  • Electrical, GFI 1) 20 amp x 120 vac
  • HTF Pumpability °F -80 °C -62
  • Fuel Winter blend diesel or #1 fuel oil
  • Hitch Choices Forged, Stamped, or Pintle
  • Diesel Generator 7.0 KWH Liquid Cooled