Description
Engineered for reliable performance and trouble-free starts for up to 101 hours of run time, the Wacker Neuson E3000 ES ground-surface heater will provide maximum flow and ensure consistent heat delivery for thawing and curing applications. The E3000ES thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 12,000 sq. ft. or provide 360,000 cu. ft. of dry heat at 84% efficiency, the highest in the industry. The ES model is a Single 3,000′ & Single Pump model, if you prefer the Dual 1,500′ Reel & Dual Pump model please look at the standard E3000 model also on sale. Both models do not include generator, but at the below savings easily add a generator and still save thousands. Wacker Item #5000620967
UPDATE 1-11-18 E3000 Sold out with Wacker for season and Thawzall also. A couple Wacker E1250’s available, but contact for pricing. Also Quest 3,000′ expandable to 4,500′ units available (2 demo units also)…excellent and solid units, but more expensive. UPDATE 11-21-17 Last two sold, but please call for other potential model savings between Wacker and Thawzall. Subject to current single digit availability, first commit…first save!
Update 11-17-17 – only 2 left, please contact if still available at the sale price of $32,650.00 a savings of over 20k!
Please get one or two prices prior to contacting us and be willing to commit based on these savings being on single digit qty, first come, first save basis. The below price includes a freight allowance and is based on the current availability of the E3000 ES. Prepayment with a cleared business check or wire transfer. We welcome a call or email (Equipment Quote Request Form above) to revisit a price (even if one is posted) based on your freight location, qty, options, payment method, etc as all off these factors effect a final price. Please obtain another price or two on the parallel model and options prior to contacting us so you can be prepared to recognize the savings and move forward with a commitment to save you hundreds, if not thousands. Most of our larger equipment posted prices (unless otherwise noted) are based on a wire transfer, include a freight allowance and customer offloading.
- With 3,000 ft. of hose and a hydraulic hose system, the E3000 ES allows for single person set-up and placement, for greater flexibility on all applications.
- Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing. One pump per hose loop means delivery of maximum Btu’s per hour.
- Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.
- Performance monitoring strobe light indicates from a distance that all systems are operating properly.
- Both this ES and the standard E3000 models are expandable with an additional hose reel and pump
- Several options are available including a 3 kW liquid-cooled diesel generator.
E3000ES | E3000ES W/ 5kW Gen | E 3000ES W/ 3kW Gen | |
---|---|---|---|
Dimensions | |||
L x W x H in | 169 x 72 x 88 | 169 x 72 x 88 | 169 x 72 x 88 |
Operating weight lb | 5,725 | 6,250 | 6,370 |
Shipping weight lb | 4,960 | 5,485 | 5,670 |
Heat transfer fluid US gal | 115 | 115 | 115 |
Hose Length ft | 3000 | 3000 | 3000 |
Quantity Hose Reels | 1 | 1 | 1 |
Quantity Circulation Loops | 2 | 2 | 2 |
Temperature monitor | Digital | Digital | Digital |
Operating data | |||
Pump performance per pump US gal/h | 265 | 265 | 265 |
Flow velocity per Circulation Loop US gal/h | 265 | 265 | 265 |
Hose pressure Normal Operating psi | 110 | 110 | 110 |
Heating power Gross Input BTU/h | 252,000 | 252,000 | 25,200 |
Heat efficiency % | 87 | 87 | 87 |
Operating temperature ° F | 180 | 180 | 180 |
Capacity Thaw (Std) ft² | 6,000 | 6,000 | 6,000 |
Capacity Thaw (w/acc) ft² | 6,000 | 6,000 | 6,000 |
Capacity Cure (Std) ft² | 6,000 | 6,000 | 6,000 |
Capacity Cure (w/acc) ft² | 12,000 | 12,000 | 12,000 |
Capacity Frost (Std) ft² | 9,000 | 9,000 | 9,000 |
Capacity Frost (w/acc) ft² | 18,000 | 18,000 | 18,000 |
Capacity Air Heat ft³ | 360,000 | 360,000 | 360,000 |
Engine performance Generator kW | 5 | 3 | |
Rated current A | 20 | 20 | 20 |
Rated voltage V | 115 | 115 | 120 |
Engine / Motor manufacturer | Kubota | Kubota | |
Engine / Motor type | 2 Cylinder Liquid Cooled | 2 Cylinder Liquid Cooled | |
Displacement in³ | 29.23 | 36.5 | |
Engine performance hp | 11.1 | 16.8 | |
Engine RPM rpm | 3000 | 3600 | |
Fuel type | Winter-Blend Diesel | Winter-Blend Diesel | Winter-Blend Diesel |
Fuel consumption Generator US gal/h | 0.6 | 0.28 | |
Fuel consumption Burner US gal/h | 1.81 | 2.2 | 1.81 |
Tank capacity Useable Fuel US gal | 115 | 115 | 115 |
Tank capacity Oil US qt | 2 | 2.64 | |
Runtime @ 100% Burner Run Percentageh | 61 | 50 | 50 |
Runtime @ 75% Burner Run Percentageh | 82 | 67 | 67 |