Description
The Wacker Neuson E3000 Ground-Surface-Hydronic Heater engineered for reliable performance and trouble-free starts for up to 140 hours of run time, the E3000 will provide maximum flow and ensure consistent heat delivery for thawing and curing applications. The E3000 thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 18,000 sq. ft. or provide 535,000 cu. ft. of dry heat at 83% efficiency, the highest in the industry. This is the Dual pump and Dual (1,500′) reel setup, if a single pump & single 3,000′ reel is sufficient please see the E3000 ES model. Please contact for current price and availability.
UPDATE 1-11-18 E3000 Sold out with Wacker for season and Thawzall also. A couple Wacker E1250’s available, but contact for pricing. Also Quest 3,000′ expandable to 4,500′ units available (2 demo units also)…excellent and solid units, but more expensive. Please obtain another price or two on the parallel model and options prior to contacting us so you can be prepared to recognize the savings and move forward with a commitment to save you hundreds, if not thousands. Most of our larger equipment posted prices (unless otherwise noted) are based on a wire transfer, include a freight allowance and customer offloading.
- With 3,000 ft. of hose and a hydraulic hose system, the E 3000 allows for single person set-up and placement, for greater flexibility on all applications.
- Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing. One pump per hose loop means delivery of maximum Btu’s per hour.
- Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.
Wacker Neuson E3000 Hyd Heater Brochure (click for pdf)
Technical specifications
E 3000 | E 3000 W/ 5kW Gen | E 3000 W/ 3kW Gen | |
---|---|---|---|
Dimensions | |||
L x W x H in | 181 x 91 x 94 | 181 x 91 x 94 | 181 x 91 x 94 |
Operating weight lb | 8,200 | 7,771 | 7,975 |
Shipping weight lb | 6,590 | 6,161 | 6,420 |
Operating weight With Lift Bail lb | 8,200 | 8,730 | 8,675 |
Shipping weight With Lift Bail lb | 6,590 | 7,120 | 7,230 |
Heat transfer fluid Capacity US gal | 115 | 115 | 115 |
Hose Lengths ft | 3000 | 3000 | 3000 |
Quantity Hose Reels | 2 | 2 | 2 |
Quantity Circulation Loops | 2 | 2 | 2 |
Temperature monitor | Digital | Digital | Digital |
Operating data | |||
Pump performance per pump US gal/h | 265 | 265 | 265 |
Flow velocity per Circulation Loop US gal/h | 265 | 265 | 265 |
Hose pressure Normal Operating psi | 110 | 110 | 110 |
Heating power Gross Input BTU/h | 385,000 | 385,000 | 385,000 |
Heat efficiency % | 83 | 83 | 83 |
Operating temperature ° F | 180 | 180 | 180 |
Capacity Thaw (std) ft² | 3,000 | 3,000 | 3,000 |
Capacity Thaw (w/acc) ft² | 6,000 | 6,000 | 6,000 |
Capacity Cure (std) ft² | 6,000 | 6,000 | 6,000 |
Capacity Cure (w/acc) ft² | 18,000 | 18,000 | 18,000 |
Capacity Frost (std) ft² | 9,000 | 9,000 | 9,000 |
Capacity Frost (w/acc) ft² | 27,000 | 27,000 | 27,000 |
Capacity Air Heat (w/acc) ft³ | 525,000 | 525,000 | 525,000 |
Rated current A | 20 | 20 | 20 |
Rated voltage V | 115 | 115 | 120 |
Engine / Motor manufacturer | Kubota Z482 | Kubota Z602 | |
Engine / Motor type | 2-Cylinder Liquid Cooled | 2-Cylinder Liquid Cooled | |
Displacement in³ | 29.23 | 36.5 | |
Engine performance hp | 11.1 | 16.8 | |
Engine RPM rpm | 3600 | 3600 | |
Fuel type | Winter Blend Diesel | Winter Blend Diesel | Winter Blend Diesel |
Fuel consumption Generator US gal/h | 0.59 | 0.28 | |
Fuel consumption Burner US gal/h | 2.75 | 3.17 | 2.75 |
Tank capacity Useable Fuel US gal | 222 | 222 | 222 |
Tank capacity Oil US qt | 2 | 2.64 | |
Runtime @ 100% Burner Run Percentageh | 81 | 81 | 81 |
Runtime @ 75% Burner Run Percentageh | 108 | 108 | 108 |